{"product_id":"vontron-ulp21-4021-commercial-21-reverse-osmosis-ro-membrane","title":"Vontron ULP21-4021 Commercial 21\" Reverse Osmosis RO Membrane","description":"\u003cdiv data-content-type=\"html\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cp\u003eYou are purchasing a Vontron ULP21-4021 21inch Commercial Reverse Osmosis RO Membrane.\u003c\/p\u003e\n\u003cp\u003eThis membrane is capable of producing 950 gallons of product water per day, and is ideal for Window Cleaning applications, along with Aquatics.\u003c\/p\u003e\n\u003cp\u003eWorking under the conditions of ultra low operating pressure, this membrane runs under approximately two thirds pressure of that regular low pressure compound membranes, and can achieve a rejection rate of as high as 99%.\u003c\/p\u003e\n\u003cp\u003ePlease see detailed manufacturers specification below:\u003c\/p\u003e\n\u003ctable style=\"width: 608px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" width=\"605\"\u003e\u003cp\u003e\u003cstrong\u003eTechnical parameter for Vontron \u003cstrong\u003eULP21-4021 \u003c\/strong\u003eRO membrane:\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eStable property desalinization rate % \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cp\u003e99\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eLowest desalinization rate %\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cp\u003e98.5\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eVolume GPD (m--3\/d) \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cp\u003e950(3.6)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eEffective membrane area ft2(m2) \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003ctd width=\"95\"\u003e\u003cp\u003e36(3.3)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eTest condition\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eTest pressure \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e150pai(1.03Mpa)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eTest fluid temperature \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e25°C\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eTest fluid density (NaCl) \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e1500ppm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eTest fluid pH\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e7.5\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eSingle RO membrane element recovery rate\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e15%\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"7\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eExtreme operating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003econditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eThe maximum operating pressure\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e600psi(2.07Mpa)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eThe maximum water supply temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e45°C\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eThe maximum water supply SDI\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e      5\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003efree chlorine concentration in water supply\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e0.1ppm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eWater supply pH scope when continuous running  \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e3~10\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eWater supply pH scope when chemical cleaning \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e2~12\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eThe maximum pressure drop of single RO membrane element  \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"99\"\u003e\u003cp\u003e15psi(0.1Mpa)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd width=\"3\"\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e","brand":"vendor-unknown","offers":[{"title":"Default Title","offer_id":57690049216837,"sku":"2555","price":169.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1043\/1551\/9301\/files\/vontron_20_inch_commercial_membrane.jpg?v=1776200020","url":"https:\/\/finest-filters.co.uk\/products\/vontron-ulp21-4021-commercial-21-reverse-osmosis-ro-membrane","provider":"Finest Filters","version":"1.0","type":"link"}